C05F7 4WD/AWD Range Actuator Control Circuit Low
A range actuator drive line sits below its expected voltage, typically because a motor lead is shorted to ground or the driver pulls it down when it should not. In a reversing gear motor each terminal is alternately the high and the low side, so a ground short on either lead shows up depending on shift direction. The TI DRV8873-Q1 is an example of a driver that reports a short to ground separately from overcurrent and open load and shuts the affected half-bridge off. Ford advises in SSM 48300 to inspect Super Duty transfer case connectors for damaged wires before condemning the motor; Magna's patent shows the motor turning a screw and sector shaft to move the range fork, so without drive the fork stays put. No maker documents C05F7; C05F8 is the high-side fault.
Likely causes
Symptoms
- 4WD service message, range change refused
- Fault may appear only when shifting in one direction
- Blown fuse for the transfer case motor possible
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: ti.com, static.nhtsa.gov, patents.google.com.