Powertrain, generic · Fuel and air metering, auxiliary emission controls
P0006 Fuel Shutoff Valve A Control Circuit Low
Check engine lightOn
EmissionsRelevant
Drive cycleRequired
Limp modeNo
The fuel shutoff valve is a solenoid valve that opens or blocks the fuel supply. On diesel engines it is usually closed without current, so that the engine stops reliably when switched off. The engine control module energises it to let fuel flow and monitors its control circuit continuously. P0006 means voltage or current in the control circuit is below the expected range, typically because of a short to ground; depending on the output stage an open circuit can also show up this way. The valve is then not energised correctly, which can prevent starting or make the engine stall.
Likely causes
Short to ground in the harness
Shorted turns in the valve coil
Corroded connector
Output driver in the engine control module faulty
Symptoms
- Check engine light on
- Hard starting or no start
- Engine stalls
Repair estimate
DifficultyMediumDIY possible
Parts and labour€50–300
Time0.5–1.5 h
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
fuel shutoff valvefuel shutoff valve wiring
Related codes