Powertrain, generic · Vehicle speed, idle control and auxiliary inputs

P05F2 Reductant Pump Supply Voltage Circuit Stuck Off

Check engine lightOn
EmissionsRelevant
Drive cycleRequired
Limp modePossible

The electric supply pump in the diesel exhaust fluid (DEF, AdBlue) tank module builds the dosing pressure for the SCR catalyst. Its supply voltage is monitored separately from the pump control circuit (P208A ff); CARB requires SCR components and their outputs to be checked for circuit faults and function. P05F2 means the pump supply cannot be switched on: after the switch-on command no voltage or feedback appears at the pump branch, so no pressure builds up. Chrysler (FCA) lists this code among those that trigger the DEF inducement: a 'Service DEF System' warning, a countdown after 50 miles and no restart after 150 miles (P241D). Without supply the pump cannot build pressure, dosing stops and NOx rises; pressure or SCR efficiency codes may follow.

Likely causes

Relay does not pull in or fuse blown
Open in the relay control or load circuit
Output driver in the engine module faulty
Electronics of the tank module faulty (no feedback)

Symptoms

  • Check engine light on
  • DEF/AdBlue warning, possibly countdown to no-restart
  • Follow-up codes for low DEF pressure or SCR efficiency

Repair estimate

DifficultyMediumWorkshop job
Parts and labour€80–900
Time0.5–3 h

Typical range across vehicles; the real cost depends on what the testing finds.

Parts involved

reductant pumpreductant pump supply circuitengine control module

Related codes

References: law.cornell.edu, static.nhtsa.gov, gsi.ext.gm.com, fordservicecontent.com.