P0A69 Drive Motor B Phase V Current
P0A69 flags a general fault in the current of phase V of drive motor B. No manufacturer documents P0A69 publicly. Phase V matters doubly on many inverters: a Hyundai patent describes designs that measure only two of the three phase currents and calculate the remaining one, so a faulty V reading also distorts the computed phase. A Caterpillar patent detects a failed sensor through the zero-sum rule of the three phase currents and can then estimate the missing value. CARB requires monitoring of electric drive components for circuit faults and plausibility. P0A6A and P0A6B are the low and high variants, P0A66 and P0A6C phases U and W, P0A60 the motor A equivalent. The driver sees a hybrid warning and motor B is taken out of service.
Likely causes
Symptoms
- Hybrid system warning and MIL
- Reduced power, motor B no longer contributes
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: patents.google.com, patents.google.com, law.cornell.edu.