P0A7A Generator Inverter Performance
P0A7A reports that the inverter stage driving the generator has signalled a fault, for example overcurrent or a failed power switch. Toyota uses the code across its hybrids and splits it with information codes. Bulletin T-SB-0142-16 covers 2012-2016 Avalon, Camry and RAV4 Hybrid with MIL on and P0A7A plus information code 122, a generator inverter fail signal caused by overcurrent; the repair replaces inverter and transaxle. A Toyota field report filed with NHTSA describes a 2006 Highlander Hybrid with P0A7A sub code 325, master warning, MIL and Check Hybrid System, traced to a fault inside the inverter assembly. P0A78 and P0A79 are the drive motor inverters, P0A3E generator inverter overheating, P0A92 generator performance.
Likely causes
Symptoms
- MIL, master warning and Check Hybrid System message
- Reduced power or vehicle will not enter ready mode
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: static.nhtsa.gov, static.nhtsa.gov.