P0AA8 Hybrid/EV Battery Voltage Isolation Sensor Circuit Range/Performance
The two isolation sensor readings, positive rail to ground and negative rail to ground, should together equal the total pack voltage. P0AA8 is the plausibility check of that relation. GM's 2016 and 2019 tables fail it when the sum of both readings differs from the measured battery voltage by more than 5 V in 40 of 50 samples, with the bias switch open, Type B, two trips. GM's 2013 table compares mid-pack sensors with the motor controller's voltage reading and allows 15 V. Mitsubishi groups P0AA8 with P0AA7 and P0AA9 as leak detection circuit faults, which on 2018 Outlander PHEVs were set falsely by noise. Unlike P0AA9 or P0AAA, the signal stays in range but is implausible; P0AA6 is a real insulation loss.