P0ACF Hybrid/EV Battery Pack Cooling Fan 3 Control Circuit/Open
Air-cooled traction batteries can use several blowers; P0ACF belongs to the third one and means the battery controller sees an open or otherwise invalid control line while it drives fan 3. CARB 1968.2 (e)(15.2.3)(B) requires the electrical inputs and outputs of the battery thermal management to be monitored like other comprehensive components. No manufacturer publicly documents this code; GM shows the method on fan 1 (P0A81): it checks the control voltage on the driver output and needs 16 failures before a Type B code is stored. Fan 1 and fan 2 have their own sets P0A81 and P0A96. Without the third blower the pack heats up faster, and power is limited.
Likely causes
Symptoms
- Hybrid or EV system warning light, often with check engine light
- Electric drive power reduced when the battery gets warm
- No fan noise from the battery area when cooling is expected
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, patents.google.com.