P0ADF Hybrid/EV Battery Negative Contactor Control Circuit Low
P0ADF reports that the drive circuit of the negative main contactor is pulled too low, typically a short to ground in the coil line. GM documents the code in its 2016-19 hybrid tables: control voltage below 5.35 V while the contactor is commanded on, 13 of 16 samples at 12.5 ms (20 of 25 in one 2016 group), Type B with two trips, enabled above about 9 to 10 V on the 12 V system. CARB 1968.2 requires this kind of circuit monitoring for hybrid outputs. Counterparts are P0ADD (open), P0AE0 (high) and, on the positive side, P0ADB. As the contactor cannot close properly, the high-voltage system does not come up and the vehicle will not drive or charge.
Likely causes
Symptoms
- Vehicle will not enter ready mode or start
- Hybrid or EV warning light and check engine light
- Charging not possible
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, law.cornell.edu, gsi.ext.gm.com.