P0AE7 Hybrid/EV Battery Precharge Contactor A Control Circuit High
P0AE7 is stored when the control line of precharge contactor A carries too much voltage for its commanded state, typically a short to the 12 V supply. In GM's 2016 and 2019 hybrid tables the high-side driver output reads between 5.27 and 19.7 V while the contactor is commanded off, 40 of 50 samples at 12.5 ms, Type B, two trips. GM's 2013 eAssist controller looks for a short to power on its low-side driver in the on state, 3 of 5 samples at 50 ms, Type B. A coil energized by a short may keep the precharge path closed when it should be open, so P0AE2 can follow. CARB requires circuit monitoring of such hybrid outputs. The negative and positive main contactor counterparts are P0AE0 and P0ADC.
Likely causes
Symptoms
- Vehicle may not start or become ready
- MIL and hybrid warning on
- Possible additional stuck-closed code P0AE2
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.