P0B6E Hybrid/EV Battery Voltage Sense K Circuit Range/Performance
In a nickel-metal hydride pack with 20 equal blocks, twenty times one block voltage should roughly equal the whole pack voltage. GM's 2012 two-mode hybrids use exactly this for P0B6E, assigned to block 11: the battery pack control module checks blocks 11 and 12, and if both scaled values deviate from the pack voltage sensor by more than 70 V in 160 of 170 samples, the code is set, Type B. The test only runs with the contactors closed for over 200 ms and no pack voltage fault active. GM's lithium-ion controllers judge channel K differently, as a frozen value that fails to follow the average cell voltage (35 of 40 samples, Type A, in the 2019 tables). No other manufacturer publishes it.
Likely causes
Symptoms
- MIL after two trips
- Less electric assist, more engine running
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, law.cornell.edu.