P0B77 Hybrid/EV Battery Voltage Sense M Circuit
P0B77 flags an open or high-resistance tap on voltage sense M, the thirteenth cell channel. GM's 2019 battery energy control module checks seven cases: adjacent cells differing by 1.3 V or more, a balancing gate reading below 36 mV, or splice voltages above 0.1 V (0.5 V at a busbar splice). M is the last channel there with the short 0.6 s window, Type A. The BAS Plus mild hybrid instead needs lines N and N-1 both below 1.4 V plus a jump over 0.5 V within 200 ms, 7 of 10 samples, Type B. Ford's TSB 23-2039 names P0B77 for 2019-2020 Fusion plug-in hybrids that no longer start and prescribes a new traction battery. Range, low and high faults on M carry their own codes.
Likely causes
Symptoms
- MIL with hybrid or EV system warning
- Vehicle may not start or go into ready mode
- Charging blocked or limited
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, static.nhtsa.gov.