P0BB3 Hybrid/EV Battery Voltage Sense Y Circuit
P0BB3 reports that the sense lead of channel Y, the twenty-fifth cell group, is no longer properly connected. GM's 16OBDG02 programme does not wait for odd voltages but calculates the resistance of the sense line and fails it above 30.00 in seven of nine samples, which is a one-trip Type A fault; the unit is missing in the table. The 2019 battery energy control module instead looks at the cell voltages themselves, for example 1.3 V between neighbours or a reading below 36 mV while that cell is being balanced, with 0.8 s of failure in 1.6 s. The eAssist mild hybrid sets it as a Type B fault when lines N and N-1 both read under 1.4 V and jump by more than 0.5 V. Low and high monitors for Y are blocked while P0BB3 is active.