P0C0B Drive Motor A Inverter Power Supply Circuit/Open
P0C0B flags a lost or interrupted supply inside the motor A inverter. GM reads it from the IGBT module status: when the gate drive supply falls below its threshold, the module reports a bias fault; on eAssist the 5 V rail below 3.5 to 4.3 V or the 15 V rail below 10.4 to 12.6 V counts, with run/crank above 7 V. The 2012 trucks enable it between 9.5 and 18 V; the 2016 to 2019 tables need 0.002 to 0.168 s of fault within short windows, Type A, one trip. Mercedes applies the code to the high-voltage supply of the inverter in the belt starter-alternator of P3 hybrids (subtypes 16 and 17) and replaces that unit. Expect loss of electric drive or engine start.
Likely causes
Symptoms
- Malfunction indicator lamp after one drive
- Electric drive or motor generator unavailable
- Engine cannot be started, only electric driving possible (Mercedes P3 hybrids)
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.