P0D11 Battery Charging System Negative Contactor A Control Circuit/Open
P0D11 is the open-circuit and driver check for negative charging contactor A. GM uses it on the Chevrolet Volt (2011, 2014) and the Cadillac ELR: the module compares the commanded driver state with what the line shows; with the driver off, an output above 4 V (2011: 2 V) means open and one close to supply voltage a short to power, and with the driver on a coil current below 57 mA is judged open as well. 40 failing samples out of 50 at 12.5 ms set it as Type A, MIL after one trip; the status of the charging HVIL source is part of the enable conditions. As on the positive side, a short to ground lies outside this test. The positive counterpart is P0D0A, plausibility, low and high are P0D12–P0D14. The vehicle will not charge.
Likely causes
Symptoms
- Malfunction indicator lamp after one trip (GM Type A)
- Vehicle does not charge
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.