P0D19 Battery Charging System A High Voltage Interlock Circuit Intermittent/Erratic
P0D19 covers a charging interlock loop that drops out and comes back, so the signal flips between valid and invalid within a short time. Loose terminals, a connector that is not fully latched, a chafing wire that only touches over bumps and vibration-sensitive solder joints are typical causes. No manufacturer documents P0D19 publicly. GM's Volt and ELR tables show the checks applied to the same loop, namely low and high limits on the sensed share of a 5 V reference, and a Ford patent explains why intermittent interlock contacts matter and how a loop can be arranged so a brief interruption does not cut propulsion. CARB requires plug-in vehicles to monitor charging components. Steady faults are P0D15–P0D18, the drive interlock intermittent code is P0A0E. Charging may stop without warning.
Likely causes
Symptoms
- Charging stops unexpectedly
- Intermittent charging system warning
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, patents.google.com.