P0DA5 Drive Motor B Inverter Voltage Sensor A Circuit Low
P0DA5 reports that the rear inverter voltage signal sits at the bottom of its range, the classic result of an open circuit, a short to ground or no high voltage arriving at all. Mitsubishi sets it in the rear motor control unit of the 2018 Outlander PHEV when, with the propulsion system active, the sensor output stays below 0.5 V, roughly 10 V on the bus, for 0.3 s. If the front unit and the generator unit report undervoltage too (P1A1B, P104D), the manual inspects the high-voltage fuse, cabling, battery section voltages and bus bars; otherwise it checks the torque of the rear battery cable at both ends before replacing the rear unit. A loose cable can therefore mimic a sensor fault. The 2023 model lists the code as a minimum range check with MIL. The high side is P0DA6.
Likely causes
Symptoms
- MIL and plug-in hybrid warning on
- Rear motor drive switched off
- Possible no-READY condition if other units also lose voltage
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes