P0DBD Hybrid/EV Battery Cell Balancing Circuit E Stuck On
With P0DBD the controller finds circuit E active when it should be idle. LG Chem's EP2730933A1 offers a way to see it: with the balancing circuit commanded off, the voltage across the diagnosis resistor should match the idle pattern; if it looks like the active pattern, current is still flowing. Group E then loses charge around the clock and drifts below the others, which in time can block charging or limit power because the lowest cell sets the lower limit. A shorted transistor is the classic cause. Ford's hybrid BECM sets P0DBD as well; the 2017 OBD summary describes a 100 ms start-up test with open contactors in which any cell of circuit E deviating more than 75 mV from the mean marks the circuit. The circuit fault is P0DBC, the inactive case P0DBE.
Likely causes
Symptoms
- MIL with battery warning
- Power reduced as group E cells drop
- Charge loss after a few days parked
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, patents.google.com, fordservicecontent.com.