P0DC5 Hybrid/EV Battery Cell Balancing Circuit G Stuck On
P0DC5 reports that the bleed switch of group G seems to stay closed. Ford lists the code for the BECM of its 2018 hybrids and plug-ins; there, a sticking circuit is inferred at start-up, with contactors open, from any of its six cells straying more than 75 mV from the pack average. A more direct test can sit in the monitoring chip. Renesas patent US9735567B2 gives each balancing terminal a comparator plus a pull-up: with the switch commanded off, the measured cell voltage should come through, and a reading near zero reveals a switch stuck in conduction. Untreated, group G keeps losing charge while parked and can end up triggering low-cell warnings. CARB lets makers watch the switches instead of every cell voltage. Circuit fault: P0DC4, inactive: P0DC6.
Likely causes
Symptoms
- Check engine light and hybrid battery warning
- Low cell voltage codes may follow after longer parking
- Electric range decreasing from day to day
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, fordservicecontent.com, patents.google.com.