P0EF0 Battery Charger Coupler Unlock Disabled - High Voltage Present
P0EF0 describes a safety lockout rather than a broken actuator: the vehicle keeps the charging connector locked because it still measures hazardous voltage at the inlet. CharIN's CCS design guide permits unlocking only below 60 V, and EVgo's interoperability guide for vehicle makers asks for release once current is close to zero, the inlet is under 60 V DC and the station has changed to state B1. If the voltage does not decay, for instance because a DC charging contactor has welded, the station leaves its output live or the vehicle's voltage measurement is wrong, the lock stays engaged and the code is logged. No manufacturer documents P0EF0 publicly. Electrical faults of the lock actuator are P0D91 to P0D98. The driver cannot remove the cable until the voltage is gone.
Likely causes
Symptoms
- Charging cable cannot be unplugged after charging
- Charging fault message, sometimes only at certain stations
- Emergency release of the connector needed
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: charin.global, site-assets.evgo.com.