P204C Reductant Pressure Sensor Circuit Low
P204C means the DEF pressure sensor output has fallen below its valid range, which points to an open signal wire, a short to ground or a missing 5 V supply. On the 6.6 L LML, GM fails anything under 0.41 V lasting 0.4 s, GM's 2018 diesel table a raw value under 5 % of the supply, and the 2025 DEF controller less than 0.45 V in 6 of 100 samples, each Type A. Ford's 2023 diesels set it under 0.2 V. On 2017 to 2019 Super Duty trucks with the 6.7 L, Ford (TSB 19-2315) found water entering connectors C3613 and C4851 of the reductant harness and replaced harness, pump/heater assembly or tank. Deutz uses failure type 11 for it on the EMR5. Lacking a pressure value, the controller suspends dosing.
Likely causes
Symptoms
- MIL on
- DEF dosing stopped, DEF warning messages
- Further reductant codes stored at the same time
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, fordservicecontent.com, static.nhtsa.gov.