P205A Reductant Tank Temperature Sensor A Circuit
P205A is the general circuit code for the temperature sensor inside the DEF tank, usually built into the level or heater unit; the separate sensor in the supply path uses P2042 ff. Deutz assigns the tank temperature (J1939 SPN 3031) to P205A: failure type 13 for an open circuit, 21 and 22 for values under or over the valid range, while the SCR-side DEF sensor (SPN 4337) stays with P2042. VW's 2014 Touareg (CNRB) stores P205A when the signal exceeds 4.70 V, i.e. the high side that an open NTC circuit produces, and keeps the low side (below 0.30 V) for P205C. Other makers split these faults into P205C and P205D. The tank temperature decides when the tank heater runs, so a fault can mean frozen DEF and an SCR warning in winter.
Likely causes
Symptoms
- MIL and DEF warning
- Tank heating not working in frost
- Speed or restart limit on some models
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: serdia.deutz.com, serdia.deutz.com, static.nhtsa.gov.