P20BB Reductant Heater A Control Circuit Low
A low reading on the heater A control circuit usually means the output or its wire is grounded, or the element pulls far more current than it should. GM's 2025 DEF module checks heater 1 (tank heater 1) in both states: switched on, a low-side drain voltage above 0.45 V or a load current above 95 A counts; switched off, the high-side voltage sitting in a low band near 0.5–0.6 V. Two seconds of failures give a Type A fault. Ford logs P20BB on circuit 1 above 15 A and lets the glow plug module report it within 250 ms; VW uses a signal voltage under 2.97 V on the 2014 Touareg. On 2020–2022 Silverado and Sierra diesels GM found the test itself setting P20BB falsely and released new DEF module calibrations (22-NA-112). Expect a warning lamp and, later, a speed limit.
Likely causes
Symptoms
- Malfunction indicator lamp, possibly with a blown heater fuse
- Message that speed will be reduced if the system is not serviced
- No DEF heating, so dosing is delayed in frost
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, static.nhtsa.gov, fordservicecontent.com, static.nhtsa.gov.