P20F6 Reductant Injection Valve Stuck Open (Bank 1 Unit 1)
Between pulses the dosing valve must seal tightly so DEF only enters the exhaust when commanded. P20F6 means the control unit concluded that the first valve on bank 1 stays open: the pressure collapses, or the pump has to work much harder to hold it than the commanded quantity explains. A Cummins patent describes this kind of check, comparing the measured pump effort with the expected flow; a strongly negative error points to a stuck-open valve, a leak or a disconnected line. FCA lists P20F6 for the Jeep Compass with the 2.0 L diesel (sales code EBS) in bulletins 18-034-20, 18-008-23 and 18-026-23 and cures it with control unit software; one case comes with system and DCU supply voltage too high. Overdosing risks ammonia slip and deposits. The stuck-closed counterpart is P208E, bank 2 is P20F7.
Likely causes
Symptoms
- Check engine light and DEF warning
- Higher DEF consumption, white deposits in the exhaust or ammonia smell
- Dosing switched off and later inducement
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: static.nhtsa.gov, static.nhtsa.gov, patents.google.com, law.cornell.edu.