P2218 NOx Sensor Heater Control Circuit/Open (Bank 2)
A NOx sensor cannot measure until its built-in heater has taken the ceramic cell to several hundred degrees, and the sensor electronics switches that heater itself. P2218 reports a break in the heater control path of the bank 2 sensor, either inside the probe or in the lead to the sensor module. No manufacturer documents the bank 2 version. The bank 1 code P2205 is well described: GM's 6.6L LML sets it when an open heater is reported longer than 10 s with the battery at 11 V or more, the 3.0L LZ0 on an open load at the heater control pin, both Type A with the MIL after one trip. Without heating, the bank 2 sensor never becomes ready. P2219 and P2220 are the shorted cases, P2221 the heater sense side.
Likely causes
Symptoms
- Malfunction indicator lamp on after one trip
- Bank 2 NOx sensor never reports ready
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, gsi.ext.gm.com.