Powertrain, generic (extended)

P247D Exhaust Gas Temperature Out of Range (Bank 2 Sensor 2)

Check engine lightOn
EmissionsRelevant
Drive cycleNot required
Limp modePossible

P247D applies to the second probe on bank 2, by analogy with P2479 normally downstream of that bank's oxidation catalyst, where the heat released by burning fuel during a regeneration is measured. It is set when the reported temperature leaves the plausible window, in practice mostly on the high side. There is no public maker document for P247D; the closest reference is Ford's 2015 diesel summary, which uses P2479 for the bank 1 position with a limit of about 1150 °C. CARB asks for out-of-range and rationality checks on such inputs. A one-sided hot reading on bank 2 often means that bank receives more fuel, while a probe that reads hot even when cold is simply faulty.

Likely causes

Too much heat in the bank 2 catalyst during regeneration
Probe reading high even on a cold engine
Leaking injector on bank 2

Symptoms

  • MIL on
  • Regeneration cancelled
  • Bank 2 probe 2 differs from its bank 1 twin

Repair estimate

DifficultyHardWorkshop job
Parts and labour€50–1,500
Time0.5–4 h

Typical range across vehicles; the real cost depends on what the testing finds.

Parts involved

egt sensor b2s2

Related codes

References: law.cornell.edu, fordservicecontent.com.