P2686 Actuator Supply Voltage C Circuit High
The high case of supply C concerns voltage that should not be there: the rail stays live although the controller has turned it off. Causes are an internal high-side switch that no longer opens or an outside wire touching battery positive. GM's 2023 and 2024 TCM tables run this check during shutdown. With output 7 disabled, a reading above 70 % of battery voltage counts as a shorted switch; the module keeps that finding in permanent memory and reports it once restarted. Battery voltage must stay within 1.5 V during the test, and GM files it as Type B: two failing trips before the lamp lights. Ford lists P2686 as the shorted-switch fault of high side driver 7 in its 2024 TR9070 table and also in the Boss 302S code list. The solenoids can no longer be switched off safely, so a limp mode is likely.
Likely causes
Symptoms
- MIL after a second trip with the fault
- Limp mode or fixed gear after restart
- Code returns after clearing once the key has been off
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, fordservicecontent.com, performanceparts.ford.com.