P2A23 Alternative Fuel Tank Shutoff Valve B Control Circuit Performance/Stuck Off
P2A23 is stored when valve B is switched on electrically, but the gas system does not react as if that cylinder had opened. Software can only judge this from pressure: after the command, the reading downstream of the tank should rise, and a tank B pressure sensor, where fitted, should fall while gas is being used. No manufacturer publishes P2A23 or its thresholds. Bus maker New Flyer devotes bulletin SMB-169 to a tank solenoid stuck closed and explains how such a cylinder is vented through the purge line before the valve is replaced. Likely reasons are a jammed armature, a closed hand valve on that tank or debris. P2A22, P2A24 and P2A25 cover the electrical faults of the same valve, P2A42 the plausibility of its pressure sensor.
Likely causes
Symptoms
- Check engine light
- Tank B stays full while the others empty
- Reduced range on gas
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes