P2A73 Alternative Fuel Hydraulic Fuel Pump Select Valve Control Circuit High
P2A73 signals that the select valve control circuit sits at a higher voltage than the commanded state allows. Typical faults are an open coil or broken wire on a low-side driven valve, which leaves the line at supply voltage, or a short to battery voltage that the output cannot pull down. The valve then stays in its spring-return position, so hydraulic flow keeps going to one tank pump whatever the command. On a multi-tank LNG truck the second tank may never be used, and the engine runs short of gas although LNG remains on board. Caterpillar's patent shows such a valve shifted by an actuator under controller command. No manufacturer publishes P2A73. Check coil resistance, the connector and the supply wire.
Likely causes
Symptoms
- Check engine light on
- Second LNG tank not used, range clearly shorter
- Gas supply stops although fuel remains
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, patents.google.com, patents.google.com.