P2A9F Alternative Fuel Return Line Valve Control Circuit Range/Performance
P2A9F covers the grey zone between a clean open and a clean short: the control circuit of the return line valve is connected, but the current or voltage the output stage measures while driving it does not fit the command. Typical reasons are a coil whose resistance has drifted, a few shorted windings, or high contact resistance in a corroded connector that lets the coil pull in only weakly or late. For a comparable tank solenoid the ROUSH CleanTech propane manual gives 6 to 35 ohms as the acceptable window, which is a useful benchmark when measuring. No manufacturer documents P2A9F or a threshold for it publicly. A valve that switches unreliably can leave vapor in the rail after a hot soak; a hydraulic lack of return flow with a sound circuit is P2AA2.
Likely causes
Symptoms
- Malfunction indicator lamp on
- Occasional hard starts after a hot soak
- Fault comes and goes with temperature or moisture
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: roushcleantech.com, law.cornell.edu.