P2ACE Reductant Temperature Sensor B Circuit Low
P2ACE means the signal of reductant temperature sensor B lies below its valid voltage band. With the NTC elements used for DEF temperature, a low voltage translates into an extremely hot reading, so a signal line rubbing through to ground, a crushed connector or DEF that has wicked into the plug and bridges the contacts are the usual suspects. No maker publishes a threshold for P2ACE. For sensor A, Deutz lists P2044-00 as a short to ground; GM's 2025 DEF controller sets the low limit of its tank sensor at 0.3 V, roughly 75 °C, which shows the order of magnitude. A false hot value can lead the controller to skip DEF heating in frost, so lines may freeze and dosing stop. Measure the sensor resistance against a temperature table and look for crystallised DEF at the connector.
Likely causes
Symptoms
- Check engine light and SCR warning
- Implausibly high DEF temperature in live data
- Frozen DEF lines in winter
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: serdia.deutz.com, gsi.ext.gm.com, law.cornell.edu.