P2BC5 Battery Charging System Positive Contactor B Stuck Closed
P2BC5 reports that positive charging contactor B still conducts after the open command, normally because its contacts have fused. Mercedes-Benz stores it, often with P2BCC, in the DC charge connection unit (N116/5, on the eSprinter N24/6) of GLE, E- and S-Class plug-in hybrids, the EQB and the eSprinter; after a DC session the vehicle refuses to start. Bulletin LI47.70-P-079912 blames current ripple, overcurrent or overvoltage from the station and contacts that part too late, and prescribes a software update plus a contactor-fault reset rather than a new unit. Mazda lists it as OBC contactor (+) stuck on in CX-90 (from 2024) and CX-70 (from 2025) plug-in hybrids and swaps Junction Box No. 2 (30-003-26). The reverse fault is P2BC6, the minus side P2BCC.
Likely causes
Symptoms
- Vehicle will not start after DC charging (Mercedes)
- High-voltage or hybrid system warning in the cluster
- Further charging blocked
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: static.nhtsa.gov, static.nhtsa.gov, static.nhtsa.gov, static.nhtsa.gov.