P2C6B Drive Motor A Phase X Current High
P2C6B flags an overcurrent in phase X of drive motor A. X, Y and Z name the second three-phase winding set of a dual-winding machine, which a Mitsubishi Electric patent shows with its own inverter bridge and a current sensor per phase. No carmaker documents P2C6B publicly. Ford's 2019 hybrid summary gives the logic for the U/V/W counterparts (P0A5F, P0A62, P0A65): the motor control unit declares overcurrent above 600 A for 400 microseconds, or above 30 A for 200 ms right after power-up, when hardly any current should flow. Real causes are a short between windings or to the housing, or a power switch that stays conducting; a sensor reading too high fakes the fault. The inverter cuts drive to protect itself. P2C6A is the low side, P2C6E and P2C71 the high faults of Y and Z.
Likely causes
Symptoms
- Hybrid or drive system warning with MIL on
- Sudden loss of electric drive, vehicle may not become ready
- Isolation fault codes stored at the same time if the winding touches the housing
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: fordservicecontent.com, patents.google.com, law.cornell.edu.