P2CAE Charge Air Cooler Coolant Pump B Control Circuit Low
P2CAE concerns the second electric pump of a charge air cooling loop: its control line is held at ground potential where the driver expects a higher level. No manufacturer documents pump B publicly. GM's published test for pump A (P023B, LT5, table 19OBDG03A) runs with the low-side driver off and flags a short to ground when output and controller ground are connected by less than 0.5 Ω, again 50 of 63 samples, Type A. What the pump then does depends on its design: a plainly switched motor may run all the time, while a smart pump that reads a missing PWM signal may fall back to an emergency mode. Look for a harness chafed on a bracket, water between pins, or an internal short in pump B. The opposite fault, a short to power, is P2CAF.
Likely causes
Symptoms
- MIL on
- Pump B runs continuously or stays in a fallback mode
- Possible power reduction when the charge air gets hot
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, gsi.ext.gm.com, patents.google.com.