P2CC7 Generator Inverter Power Supply B Circuit High
P2CC7 is set when supply B of the generator inverter exceeds its upper limit. Gate inputs of IGBTs tolerate only a limited voltage, so overvoltage on the driver rail puts the switches at risk and the inverter is normally shut down. Ford shows that such rails have a hard ceiling: in its 2019 hybrid OBD summary a motor or generator gate drive supply above 15.08 V counts as a fault, although Ford reports it under a rotor position circuit voltage check, and for the variable voltage converter the window runs from 0.1 V to 15.3 V. No manufacturer documents P2CC7 publicly. A faulty internal regulator or a short between supply rails is most likely. CARB demands circuit monitoring of hybrid components. Siblings: P2CC5, P2CC6; supply A high is P0E11.
Likely causes
Symptoms
- Hybrid system warning light and MIL on
- Generator blocked, battery no longer charged while driving
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: fordservicecontent.com, law.cornell.edu, gsi.ext.gm.com.