P2D35 Hybrid/EV Battery Inductive Charging System High Voltage Interlock Circuit Performance
The inductive charger feeds its rectified DC power into the high-voltage system, so its connectors are usually part of a high voltage interlock loop (HVIL), a low-voltage circuit that breaks as soon as a plug or cover is opened. P2D35 means this loop delivers a signal, but not the one expected, for instance a level that does not track the test source being switched. A clear open is P2EB4. No manufacturer documents P2D35 publicly. GM's Volt tables show how a charging interlock is judged: the module sources 5 V into the loop and treats a reading below 30 % of that reference as a fault, Type A (P0D17 in 14OBDG01). Partly seated plugs, worn or corroded terminals and chafed wires are typical. CARB expects charging faults to be detected. Wireless charging stays blocked until the loop is sound.
Likely causes
Symptoms
- Inductive charging is refused
- Fault appears after work on the underbody or after driving through deep water
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, law.cornell.edu, en.wikipedia.org.