P2DBA Battery Charging System B High Voltage Interlock Circuit High
P2DBA flags an interlock signal of charging system B that reads too high. A loop fed from a test source and measured at its far end shows a raised level when it is shorted to a supply voltage, or, depending on the circuit, when added resistance or a break lets the measuring input float upward. No manufacturer documents P2DBA publicly. GM checks the A-side loop of the Volt in two states (P0D18): with the 5 V source off, a reading above 24 % of reference counts as a fault, with it on, one above 44 %; both are Type A in the 2011 and 2014 tables. Telling a short to voltage from an open therefore needs both states. The low counterpart is P2DB9. Charging through path B stays blocked.
Likely causes
Symptoms
- No charging via path B
- Charging system warning message
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com.