P2E27 Drive Motor A Phase X-Y-Z Current Sensor Correlation
P2E27 compares the three current sensors of phases X, Y and Z of drive motor A with each other. Mitsubishi Electric's patent joins the X, Y and Z windings in a star, so their currents must add up to almost zero at every instant; a clear residual means at least one sensor is wrong, even if every reading passes its own checks. No manufacturer documents P2E27 publicly. GM's U-V-W counterpart P0BFD shows the limits: an absolute sum of 110 A for 0.02 s on the 2016 Volt or for 0.0032 s within 0.0038 s in a 2019 table, and above 156 A on the 2016 Cadillac ELR, all Type A. GM's eAssist skips its balance check while a single sensor code is set, because that code already names the culprit; the correlation alone cannot. Single faults: P2E1B to P2E26.
Likely causes
Symptoms
- Hybrid warning lamp and MIL
- Electric drive limited or temporarily switched off
- No single sensor code stored alongside
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: image-ppubs.uspto.gov, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.