U010E Lost Communication With Reductant Control Module
U010E concerns the reductant control module that runs dosing, pump and heaters of a diesel SCR system with urea solution (DEF/AdBlue). GM's 2017 small-diesel table expects frame $092 and several $4Cx/$4Ex frames on bus B and, after 10 s of silence, records a Type A fault with MIL on the first trip, unless bus B is off (U0074). GM's 2025 central gateway judges its DEF controller differently: messages overdue by 2.5 periods for 6.5 s with battery above 7 V give Type B. For Ram 3500–5500 cab chassis with the 6.7 L Cummins (2012), bulletin 18-012-13 brought ECM software against needless MIL with U010E. Without the module no reductant is dosed, NOx rises and the inducement logic may cap speed. U040F covers invalid data.
Likely causes
Symptoms
- MIL and DEF/AdBlue warning
- Countdown to speed limit or restart block
- Further SCR codes such as P20EE
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, static.nhtsa.gov.