U0552 Invalid Data Received From Running Board Control Module B
A second running board controller only makes sense where each side of the vehicle has its own electronics. A 2004 Ford patent for powered boards has one central module drive the left and right boards separately, so a design with one node per side is plausible, but no manufacturer publishes which side B would be. Ford, the best documented user of power running boards, fits a single RBM in the F-150, Super Duty and Expedition/Navigator; it drops from Auto to Off after a battery undervoltage event with U3003:16 (SSM 50154). U0552 means messages from module B arrive but fail plausibility; U0251 would mean they are missing. No manufacturer documents U0552 publicly. Typically one board stops deploying or the feature switches itself off.
Likely causes
Symptoms
- Running board on one side no longer deploys or retracts
- Running board setting changes from Auto to Off without driver input
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: static.nhtsa.gov, static.nhtsa.gov, patents.google.com.