U350A Control Module Input Power C Circuit High
U350A is the overvoltage code for supply C. GM's electric brake booster (2016–2019 hybrid tables) logs it when voltage sensor 2 on the motor driver supply exceeds 19.8 V for 90 s at speeds above 4 mph, Type A, so a single failing trip lights the MIL. The limit is higher than the 16 to 18 V thresholds used for feeds A and B because the motor stage tolerates more, yet a lasting excess is treated as serious since it threatens the power transistors. The pass condition is a straight drive over 3.1 miles or more. Such values rarely arise in a healthy 12 V system: think of a failed generator regulator or DC/DC converter, jump-starting from a 24 V source, or, with normal battery voltage, an internal sensing error.
Likely causes
Symptoms
- MIL and brake warning on the first trip
- Brake assist reduced or switched off
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, law.cornell.edu.