P06F1 Reductant Control Module Internal Temperature Sensor Range/Performance
Some SCR diesels have a separate reductant control module that drives the DEF pump, heaters and dosing valve – Ford calls it the pump motor controller (fault above 130 °C under P20FF), GM's L5P an SCR power module. It measures its own board temperature with an internal sensor to protect itself from heat. P06F1 means the signal is electrically valid but implausible – it jumps, freezes or differs from comparison temperatures such as ambient or tank temperature after a long stop. Circuit faults are P06F0, P06F2 and P06F3. No manufacturer document available to us uses P06F0–P06F3; Ford and GM report related faults under P20FF or own codes. Without a valid temperature the module limits or stops heaters and pump, so dosing is restricted and an SCR warning, up to a start lock countdown, may follow.
Likely causes
Symptoms
- Check engine light or SCR warning
- Message to check AdBlue system, possibly countdown to start lock
- DEF heating or pump inactive (no thawing in frost)
- Driveability usually unchanged
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, fordservicecontent.com, gsi.ext.gm.com.