P06F2 Reductant Control Module Internal Temperature Sensor Circuit Low
Some SCR diesels have a separate reductant control module that drives the DEF pump, heaters and dosing valve – Ford calls it the pump motor controller (fault above 130 °C under P20FF), GM's L5P an SCR power module. It measures its own board temperature with an internal sensor to protect itself from heat. P06F2 means the signal is below its minimum; with the usual NTC voltage divider that is a short to ground, and the reading appears implausibly hot. The opposite fault is P06F3, an implausible reading P06F1. No manufacturer document available to us uses P06F0–P06F3; Ford and GM report related faults under P20FF or own codes. Without a valid temperature the module limits or stops heaters and pump, so dosing is restricted and an SCR warning, up to a start lock countdown, may follow.
Likely causes
Symptoms
- Check engine light or SCR warning
- Message to check AdBlue system, possibly countdown to start lock
- DEF heating or pump inactive (no thawing in frost)
- Driveability usually unchanged
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: law.cornell.edu, fordservicecontent.com, gsi.ext.gm.com.