P0BA0 Hybrid/EV Battery Voltage Sense U Circuit Range/Performance
P0BA0 tells the technician that channel U gives a number, but the number does not move with the pack. GM checks this rationality only on lithium-ion systems, since the two-mode NiMH trucks end at block 20. The Cadillac ELR of 2016 reacts to the smallest movement: when the average cell voltage changes by more than 0.006 V, cell U must follow, and 20 failures in 40 samples at 200 ms set a Type A fault. The Volt of the same year looks at 0.022 V of average movement and a 7 s in 8 s window, the 2019 hybrid processor at 0.005 V with 35 of 40 samples, and eAssist at half the average movement, Type B. Circuit, low and high faults are excluded before the test runs, so wiring is less likely than the controller.
Likely causes
Symptoms
- MIL, often without driver-noticeable change
- Electric range may be reduced
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.