P0BA2 Hybrid/EV Battery Voltage Sense U Circuit High
P0BA2 flags an excessive voltage on channel U. GM's eAssist mild hybrid uses the lowest threshold of the documented systems: above 4.65 V in 7 of 10 samples with the 12 V supply above 8.8 V, Type B. The 2016 Volt and the 2019 battery controller set it at 4.8 V or more held for 1.4 s within 2 s, Type A; the 16OBDG02 programme at above 4.90 V in 14 of 18 samples, Type A. As with the low code, the high test is held back while an open sense line or module communication fault is active. Channel U does not exist on the twenty-block two-mode trucks. Before replacing parts, the actual cell voltage should be measured, because a lead touching a higher potential is far more common than a real overcharge.
Likely causes
Symptoms
- MIL and hybrid or EV warning
- Charging stopped early
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.