P0BE2 Drive Motor Inverter Temperature Sensor F Circuit Low
P0BE2 is set when the voltage from inverter temperature sensor F, the phase W thermistor in GM's motor B inverter, drops below the valid window. Because GM pairs an NTC element with a pull-up resistor, a short to ground is converted into a temperature far above anything the inverter can survive. Limits found in GM's tables: more than 170 °C for 2.5 of 3.5 s, Type B, two trips (2016 and 2018); more than 159 °C for 6.25 of 8.75 s, Type A (2019); more than 130 °C, Type A (2011 Volt); more than 125 °C, Type B (2012 and 2013 two-mode trucks). Genuine overheating of this phase has its own code, P0C16. The thermistor is part of the inverter, so it is rarely replaced on its own.
Likely causes
Symptoms
- Malfunction indicator lamp and hybrid warning
- Power of drive motor B strongly limited
- Engine runs more often in hybrid operation
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.