P0BE5 Drive Motor A Phase U Current Sensor Circuit
The inverter of drive motor A measures the current in each motor phase with a current sensor; the controller needs these values for torque control and overcurrent protection. P0BE5 is the general circuit code for the phase U sensor, used for an electrical fault that is not classed as offset, low or high. No manufacturer documents this exact code publicly; GM's hybrid tables (2011 Volt through 2019) only use the siblings P0BE6, P0BE7 and P0BE8, and CARB requires hybrid sensor circuits to be monitored. Without a reliable phase U reading the inverter typically switches to a reduced or alternate control mode, so motor A loses power. The sensor sits inside the inverter, which usually means inverter replacement.
Likely causes
Symptoms
- Hybrid system warning and malfunction indicator lamp
- Reduced power from drive motor A
- Possible loss of electric drive
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes