P0BE8 Drive Motor A Phase U Current Sensor Circuit High
P0BE8 is the high-side counterpart of P0BE7: the phase U current sensor of the motor A inverter reports a value above its valid range. GM's tables set it above 700 A for 0.05 of 0.1 s (2016) or 0.1 of 0.15 s (2019), Type A, one trip; above 800 A, Type A, on the 2011 Volt; above 700 A, Type B, on the 2012 two-mode trucks; and above 440 A, Type B, two trips, in the BAS Plus (eAssist) table. A reading this high without matching battery current points to the sensor or its supply rather than real current; genuine excess current is covered by separate overcurrent codes such as P0C01. The inverter then uses a fallback control strategy and motor A delivers less torque.
Likely causes
Symptoms
- Malfunction indicator lamp and hybrid warning
- Reduced power from drive motor A
- Possible shutdown of electric drive
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.