Powertrain, generic · Hybrid propulsion

P0BEF Drive Motor A Phase W Current Sensor Circuit Low

Check engine lightOn
EmissionsRelevant
Drive cycleNot required
Limp modePossible

P0BEF indicates that the phase W current sensor of the motor A inverter delivers a signal below its valid range. GM's limits: below -700 A for 0.05 of 0.1 s (2016 tables) or 0.1 of 0.15 s (2019), Type A; below -800 A, Type A, on the 2011 Volt; below -700 A, Type B, on the 2012 two-mode trucks; below -440 A, Type B, two trips, in the BAS Plus (eAssist) table. These readings lie far outside real phase currents, so a sensor output stuck near ground, a failed sensor or a supply fault is the likely cause. In the eAssist system this fault puts current control into a mode that ignores the sensors, and it disables the U-V-W correlation check P0BFD, so motor A runs with reduced output.

Likely causes

Failed phase W current sensor inside the inverter
Sensor signal or supply pulled to ground on the sensor board
Poor contact at an internal or external inverter connector

Symptoms

  • Malfunction indicator lamp and hybrid warning
  • Reduced power or no assist from drive motor A

Repair estimate

DifficultyShop_onlyWorkshop job
Parts and labour€150–4,000
Time1–6 h

Typical range across vehicles; the real cost depends on what the testing finds.

Parts involved

drive motor a phase w current sensorwiring harnesshybrid control module

Related codes

References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.