P0BEB Drive Motor A Phase V Current Sensor Circuit Low

Check engine lightOn
EmissionsRelevant
Drive cycleNot required
Limp modePossible

P0BEB reports that the phase V current sensor in the motor A inverter outputs a signal below its valid range. GM compares the converted current with a lower limit: below -700 A for 0.05 of 0.1 s (2016 tables) or 0.1 of 0.15 s (2019 table), Type A, one trip; below -800 A, Type A, on the 2011 Volt; below -700 A, Type B, two trips, on the 2012 two-mode trucks. Real phase currents never reach these values, so the code points to an electrical fault such as a sensor output pulled toward ground or a dead sensor. Unlike P0BEA, the sensor is not just shifted but out of its measuring range. Motor A is then run in a restricted mode.

Likely causes

Failed phase V current sensor inside the inverter
Sensor signal or supply pulled to ground on the sensor board
Poor contact at an internal or external inverter connector

Symptoms

  • Malfunction indicator lamp and hybrid warning
  • Reduced power from drive motor A
  • Possible shutdown of electric drive

Repair estimate

DifficultyShop_onlyWorkshop job
Parts and labour€150–4,000
Time1–6 h

Typical range across vehicles; the real cost depends on what the testing finds.

Parts involved

drive motor a phase v current sensorwiring harnesshybrid control module