P0C05 Drive Motor A Phase U-V-W Circuit/Open
P0C05 detects an open or missing phase between the inverter and drive motor A. GM checks each phase as the rotor passes its axis: if the peak phase axis current stays below 9 A while at least 23 A is commanded, with the rotor within 30 degrees of that axis and over 35 V on the inverter, about 200 failed samples set the code. It is Type A, one trip, on the Volt and two-mode trucks and Type B, two trips, on eAssist. Jeep lists it on the 2018/19 Wrangler eTorque with P0C01, curing it by software or a new motor generator unit. Volvo uses it in the rear axle inverter of 2020 to 2022 PHEVs and advises clearing it and test-driving before replacing parts. Expect reduced electric power.
Likely causes
Symptoms
- Propulsion system performance message or warning lamp
- Reduced electric drive power
- Loss of 12 V charging or noise from the motor generator on mild hybrids
Repair estimate
Typical range across vehicles; the real cost depends on what the testing finds.
Parts involved
Related codes
References: gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com, gsi.ext.gm.com.